The continuous assignment statement shall place a continuous assignment on a net data type. The net may be
explicitly declared, or may inherit an implicit declaration in accordance with the implicit declarations rules
defined in 3.5.
Assignments on nets shall be continuous and automatic. This means that whenever an operand in the righthand
side expression changes value, the whole right-hand side shall be evaluated and if the new value is different
from the previous value, then the new value shall be assigned to the left-hand side.
Examples:
Example 1—The following is an example of a continuous assignment to a net that has been previously
declared:
wire mynet ; assign (strong1, pull0) mynet = enable ;
Example 2—The following is an example of the use of a continuous assignment to model a 4-bit adder with
carry. The assignment could not be specified directly in the declaration of the nets because it requires a concatenation
on the left-hand side.
module adder (sum_out, carry_out, carry_in, ina, inb); output [3:0] sum_out; output carry_out; input [3:0] ina, inb; input carry_in; wire carry_out, carry_in; wire [3:0] sum_out, ina, inb; assign {carry_out, sum_out} = ina + inb + carry_in; endmodule
Example 3—The following example describes a module with one 16-bit output bus. It selects between one of
four input busses and connects the selected bus to the output bus.
module select_bus(busout, bus0, bus1, bus2, bus3, enable, s); parameter n = 16; parameter Zee = 16’bz; output [1:n] busout; input [1:n] bus0, bus1, bus2, bus3; input enable; input [1:2] s; tri [1:n] data; // net declaration // net declaration with continuous assignment tri [1:n] busout = enable ? data : Zee; // assignment statement with four continuous assignments assign data = (s == 0) ? bus0 : Zee, data = (s == 1) ? bus1 : Zee, data = (s == 2) ? bus2 : Zee, data = (s == 3) ? bus3 : Zee; endmodule
The following sequence of events is experienced during simulation of this example:
a) The value of s, a bus selector input variable, is checked in the assign statement. Based on the value
of s, the net data receives the data from one of the four input buses.
b) The setting of data net triggers the continuous assignment in the net declaration for busout. If
enable is set, the contents of data are assigned to busout; if enable is 0, the contents of Zee
are assigned to busout.
6.1.2 The continuous assignment statement