首页 > 其他 > 详细

PowerDesin把name复制到Comment,把Comment复制到Name

时间:2017-06-09 09:24:40      阅读:289      评论:0      收藏:0      [点我收藏+]

PowerDesin把name复制到Comment,把Comment复制到Name的方法:

PowerDesigner->Tools->Execute Commands->Edit/Run Scripts

一:将Name中的字符COPY至Comment中  

Option   Explicit   
ValidationMode   =   True   
InteractiveMode   =   im_Batch  
  
Dim   mdl      the   current   model  
  
   get   the   current   active   model   
Set   mdl   =   ActiveModel   
If   (mdl   Is   Nothing)   Then   
      MsgBox   "There   is   no   current   Model "   
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then   
      MsgBox   "The   current   model   is   not   an   Physical   Data   model. "   
Else   
      ProcessFolder   mdl   
End   If  
  
   This   routine   copy   name   into   comment   for   each   table,   each   column   and   each   view      of   the   current   folder   
Private   sub   ProcessFolder(folder)   
      Dim   Tab   running     table   
      for   each   Tab   in   folder.tables   
            if   not   tab.isShortcut   then   
                  tab.comment   =   tab.name   
                  Dim   col      running   column   
                  for   each   col   in   tab.columns   
                        col.comment=   col.name   
                  next   
            end   if   
      next  
  
      Dim   view   running   view   
      for   each   view   in   folder.Views   
            if   not   view.isShortcut   then   
                  view.comment   =   view.name   
            end   if   
      next  
  
         go   into   the   sub-packages   
      Dim   f      running   folder   
      For   Each   f   In   folder.Packages   
            if   not   f.IsShortcut   then   
                  ProcessFolder   f   
            end   if   
      Next   
end   sub  

二:将Comment中的字符COPY至Name中

Option   Explicit   
ValidationMode   =   True   
InteractiveMode   =   im_Batch  
  
Dim   mdl      the   current   model  
  
   get   the   current   active   model   
Set   mdl   =   ActiveModel   
If   (mdl   Is   Nothing)   Then   
      MsgBox   "There   is   no   current   Model "   
ElseIf   Not   mdl.IsKindOf(PdPDM.cls_Model)   Then   
      MsgBox   "The   current   model   is   not   an   Physical   Data   model. "   
Else   
      ProcessFolder   mdl   
End   If  
  
Private   sub   ProcessFolder(folder)   
On Error Resume Next  
      Dim   Tab   running     table   
      for   each   Tab   in   folder.tables   
            if   not   tab.isShortcut   then   
                  tab.name   =   tab.comment  
                  Dim   col      running   column   
                  for   each   col   in   tab.columns   
                  if col.comment="" then  
                  else  
                        col.name=   col.comment   
                  end if  
                  next   
            end   if   
      next  
  
      Dim   view   running   view   
      for   each   view   in   folder.Views   
            if   not   view.isShortcut   then   
                  view.name   =   view.comment   
            end   if   
      next  
  
         go   into   the   sub-packages   
      Dim   f      running   folder   
      For   Each   f   In   folder.Packages   
            if   not   f.IsShortcut   then   
                  ProcessFolder   f   
            end   if   
      Next   
end   sub  

本文地址:http://www.cnblogs.com/ajiangg/p/6970225.html

PowerDesin把name复制到Comment,把Comment复制到Name

原文:http://www.cnblogs.com/ajiangg/p/6970225.html

(0)
(0)
   
举报
评论 一句话评论(0
关于我们 - 联系我们 - 留言反馈 - 联系我们:wmxa8@hotmail.com
© 2014 bubuko.com 版权所有
打开技术之扣,分享程序人生!